A 45-second loop of the PlateLogic workflow: data in as a CSV from any plate reader or as images of every well, a configurable image pipeline run on all 96 wells, configurable calculation nodes, a choice of curve fits with unknowns interpolated, your own QC rules across a batch of plates, then reports, trending in TrendLab and 21 CFR Part 11 with AuditSafe.
1 / 6 · Import
Numbers or images, from any reader.
The CSV export from any plate reader, or images of every well, into one analysis.
Fully configurable plate analysis, from any plate reader's CSV or from well images: your image pipeline, your calculations, your curve fits and your QC rules.
Request a free trial at totallab.comYour software won’t do what you need? Ask TotalLab.
PlateLogic takes the CSV export from virtually any plate reader, including Molecular Devices, Tecan, BMG LABTECH, BioTek and Thermo Fisher instruments, so every reader in the lab feeds one analysis. It can also take images of the plate, such as zebrafish or particles in each well.
Build the image analysis from configurable nodes: blur, threshold, binary mask, edge detection and object counting, each with settings you choose, and preview the result before it runs on the image in every well. Accurate counting of cells, particles, zebrafish or anything else in a plate.
The same calculation pipeline runs on the values from your image analysis or on the CSV from any plate reader. Program everything downstream of the numbers as nodes: subtract blanks, average wells, divide one well by another, normalize to controls, fit curves and apply QC rules. Every node and every setting is yours to configure, and the finished pipeline is saved as a template, so the next plate goes straight to results.
Choose from linear, quadratic, point-to-point, 4PL, 5PL and other fit models, with automated goodness-of-fit checks, residual analysis and outlier detection, and unknowns interpolated from the curve.
Set your own acceptance criteria, such as high and low control limits or curve criteria, and every plate in a batch is checked and flagged automatically. Share templates with teams, sites or CDMO partners by email so everyone runs exactly the same analysis.
Produce formatted, audit-ready reports, and send results to TrendLab to track standards, controls and samples over time. With AuditSafe, PlateLogic meets 21 CFR Part 11, EU Annex 11, GAMP 5 and ALCOA+, with an IQ/OQ package for every regulated deployment.
See PlateLogic on your own assay data. It works with the plate readers you already have, with online or offline activation and unlimited users on each licensed computer. Working under GMP? AuditSafe adds 21 CFR Part 11 and Annex 11 controls.
Request free trial